Share

Veolia Validated UV disinfection for wastewater treatment plant

Applications: Wastewater

Customer

Veolia Water Solutions & Technologies Australia

Application

Waste water UV disinfection

Project Background

The construction of the 450 hectare Bingara Gorge community which included an 18-hole golf course required a Recycled Water Treatment Plant as it is a residential development located outside the normal wastewater network serviced by Sydney Water. Our customer Veolia was approached to build the project. The treated water would be used for irrigation on the golf course and gardens as well as for flushing toilets. The treated water would need to meet the stringent standards of the NSW Code of Practice – Management of private recycled water schemes as well as the Australian Guidelines for Water Recycling. The project also wanted to achieve the Housing Industry Association’s first GreenSmart Advanced Estate accreditation for its environmentally friendly efforts.

The Recycled Water Treatment Plant was designed with a 4-barrier treatment process consisting of coarse filtration, ultrafiltration, UV Disinfection and chlorination.

UV Requirements

  • Pre validated to DVGW, ÖVGW and SVGWstandards
  • Peak flow rate of 14 m3/hr
  • UV dose of 160 mJ/cm2
  • Compact design

UV Guard’s Solution

  • 8 x Aquafides 1AF400T systems in two banks of four, each bank treating 7 m3/hr

The Aquafides 1AF400T system was selected for the project due to a number of features it possesses. It is suited towards applications where UV Transmittance (%UVT) is as low as 2% making it is the only 1 lamped validated system available on the market for such a poor water quality. The 1AF400T system was also selected for its compact and energy efficient design. By installing the systems in two banks of four, the required high UV dose of 160 mJ/cm2 was able to be achieved and the design allowed for a level of redundancy – UV disinfection can be provided even when a unit is being serviced.

For more information on the Wilton recycled water treatment plant project click here.

If you have a wastewater or municipal treatment enquiry where UV disinfection is a requirement, contact a process engineer today

  • Freshwater Systems Australia Case Study – UV Guard

    Discover how Freshwater Systems Australia and UV Guard's strategic partnership drives success in delivering water treatment solutions across healthcare, pharmaceutical, and domestic industries. Learn about our collective technical expertise, and commitment to meeting stringent water quality guidelines.

  • Combatting High Chlorine for Swim School Health & Safety

    UV Guard installed a tailored solution for improving water quality at a popular NSW swim school, bringing chlorine levels down to meet NSW Health requirements and ensuring a safer and more enjoyable environment for all.

  • Stopping the spread of viruses in aquaculture research facility

    The aquaculture facility had multiple research stations all independently researching different fish species at the same time, and each one of these stations required its own UV system to treat the water entering that specific area. Additionally, all seawater entering the research facility needed to be treated. All UV systems needed to be selected to achieve minimum UV doses to achieve sufficient inactivation of viruses such as white spot.

  • Proof low pressure UV treatment is an effective approach for public swimming pools

    A 25m public swimming pool was struggling to implement consistent reductions in chloramine (combined chlorine) levels – especially during peak swimming periods. In addition, enrolments at their learn to swim classes had failed to increase for the past 2 years due to parental concerns about allergic reactions to chloramines such as trichloramines.

Get in touch

This website has lots about us.
But it’s your needs that matter most.
Let’s talk.

Newsletter

Stay up-to-date with our very latest news, technology, offers and events.